The Lancer Probe Assembly with Springs is the primary liquid-level and temperature sensing component for the water bath. It sends resistance signals to the control board to manage the refrigeration cycle, ensuring the compressor builds a consistent ice bank without freezing the entire tank solid.
Problem Solved: Corrects refrigeration logic failures where the compressor runs 24/7 or fails to kick on at all. The spring-loaded design ensures the probe maintains a secure electrical ground against the tank frame, preventing 'ghost' readings that disrupt cooling.
Symptoms of Failure: An oversized ice bank that 'bridges' and blocks the agitator propeller, beverages serving warm despite power to the unit, or the refrigeration deck short-cycling.